Our autoclave represents the highest technical level in China & In world, we have many top customers in China and in world , for example, AVIC,Nuclear Industry Research Institute,Special Material and Technology Research Institute and Zhongnan University Laboratory.
The autoclave can be customized by your requirements
Autoclave can realize temperature ,pressure ,cooling and process parameters timing ,real-time on line controlled equipment .Mainly device into below systems:
1. tightness of tank :it is made from tank ,tank door ,high temperature motor ,air duct heat partition layer to form into one high pressure resistant ,high temperature tank
2. safety interlock : it is made from pressure automatic interlock ,manual interlock ,over pressure alarm device.
3. Quickly open door device :manual or automatic quickly open design ,even If power off ,it can start and close the door
4. Sealing device: the door adopt silica gel filling air ,it can bear 500 degree ,forming into one high temperature high pressure sealed container
5. Pressure system: pressure transfer and control system include air compressor ,storage tank ,pressure control valve ,pipe ,pressure transformer ,and pressure gauge .
6. Heating system: stainless steel heating pipe ,high temperature fan ,wind plate ,insulation layer ,temperature control system .heating power satisfy with inside tank max temperature requirement and raising temperature
7. Temperature circulation system :it made up of circulation fan ,wind plate ,and guide flow cover to improve heating transfer and circulation form into uniform temperature
8. Vacuum system :it made up of vacuum pump ,pipe ,vacuum gauge ,vacuum vale ,to supply composite material vacuum condition
9. Automatic control system: adopt PLD and fuzzy control ,to realize the pressure ,temperature ,cooling and so on full process high -precision control and in time record
Main technology date :
Item |
data |
Effective diameter |
500-5000mm |
Effective length |
1000-40000mm |
Working temperature |
100-450 degree |
Working pressure |
0.5-5.0Mpa |
Raising temperation speed |
0.1Mpa/min continuous adjustment |
Temperature go down speed |
+ 0.01Mpa
- |
Cooling ways |
0.5-7 degree/min continuous adjustment |
Point difference temperature |
0.5-7 degree/min continuous adjustment |
Control temperature and test temperature point |
Water cool and wind cool |
Vacuum degree of cavity |
-0.098Mpa (absolutely pressure ) |
Extra vacuum pipe |
Extract 2-20 pipe extract and test is independent |
Test vacuum pipe |
Test 2-20 pipe extract and test is independent |